Accuracy of the planar compliant mechanisms

Authors

  • Mustafa Hasan
  • Ljubomir Lilov

Keywords:

Accuracy, Compliant Mechanisms, Flexure Hinges

Abstract

In the recent years a class of devices called compliant mechanisms is in the focus of many investigations. Their use in the design of modern devices, especially in micro-electro-mechanical systems (MEMS), is inevitable because of the difficulty in fabricating rigid-body joints and assembling parts. Compliant mechanisms rely upon elastic deformation to perform their function of transmitting and/or transforming motion and force. Flexural pivot-based designs use narrow sections connecting relative\-ly rigid segments. Thus, compliance is lumped to a few portions of the mechanism. The introduction of the elastic pivots instead of the rigid-body joints leads to certain deviations in the performance of the compliant mechanisms compared with the analo\-gous rigid-body linkages. These deviations are the object of study in the paper. Based on the graph theory, a method for effective estimation of the accuracy of compliant mechanisms with flexural pivots is elaborated and practical examples are considered.

Downloads

Published

2008-12-12

How to Cite

Hasan, M., & Lilov, L. (2008). Accuracy of the planar compliant mechanisms. Ann. Sofia Univ. Fac. Math. And Inf., 98, 203–229. Retrieved from https://ftl5.uni-sofia.bg./index.php/fmi/article/view/139